SEC-Z512MGX質(zhì)量流量控制器
簡(jiǎn)要描述:Z512
產(chǎn)品型號(hào):
廠商性質(zhì):經(jīng)銷(xiāo)商
更新時(shí)間:2025-09-11
訪  問(wèn)  量:1419
  Z512, Z522 Digital / Analog
  Mass Flow Controller / Meter
  SEC-Z512MGX SEC-Z522MGXN SEC-Z522MGX
  SEC-Z512X SEC-Z522XN SEC-Z522X
  SEF-Z512MGX SEF-Z522MGXN SEF-Z522MGX
  SEF-Z512X SEF-Z522XN SEF-Z522X
  Full-scale flow rate MR/MG number
  (N2 conversion flow rate) #R01:10SCCM
  #R1.5:17.5SCCM
  #01:30SCCM
  #1.5:55SCCM
  #02:100SCCM
  #2.5:175SCCM
  #03:300SCCM
  #3.5:550SCCM
  #04:1SLM
  #4.5:1.75SLM
  #05:3SLM
  #5.5:5.5SLM
  #06:10SLM
  Valve Type
  Flow rate at fully closed control valve
  Flow rate control range
  Flow rate measuring range (SEF)
  Operating temperature
  Response
  Linearity
  Repeatability
  50 to 300 kPa (d)
  #5.5, #06: 100 to 300 kPa (d)
  Operating differential pressure (SEF)
  MAX. Operating pressure
  Pressure resistance
  Leak Integrity
  Flow rate setting signal
  Flow rate output signal
  Wetted materials
  1/4 inch VCR equivalent
  Option: 1.125 inch IGS
  Mounting orientation
  *1 The gas type and full scale settings for the SEC(SEF)-Z512MGX, Z522MGX, and Z522MGXN can be changed
  by the operator, using special software.
  *2 The flow rate precision guaranteed temperatures conform to SEMI E56-1296 standards. The precision is that
  associated with the full-scale MR and MG number values.
  *3 IGS: Integrated Gas System
  * SCCM and SLM are notations indicating the gas flow rate (mL/min, L/min, at 0°C and 101.3 kPa).
  Mass flow controller model *1 SEC-Z512KX
  Mass flow meter model *1 SEF-Z512KX
  O: Normally open C: Normally closed
  ≤ 2% F.S.
  2-99% of F.S.
  1/2SCCM
  MR/MG number
  #6.5: 22SLM
  #07: 30SLM
  #08: 50SLM
  0-99% of F.S.
  Accuracy *2 ±1.0%F.S. ±1.0%S.P.(Flow rate>25%F.S.)
  ±0.25%F.S.(Flow rate≤25%F.S.)
  5 to 50°C (recommended temperature range: 15 to 45°C)
  ≤ 1 second: Over full flow rate range
  ≤ ±0.5% F.S.
  ≤ ±0.2% F.S.
  Operating differential pressure 50 to 300 kPa (d) 200 to 300 kPa (d)
  ≤ 300 kPa (d)
  450 kPa (g)
  1000 kPa (g)
  ≤ 5 x 10-12 Pa·m3/s (He)
  0.1 to 5 V DC (2% to F.S.); Input impedance 1 MÙ or higher
  0 to 5 V DC (0% to F.S.); Minimum load resistance 2 kÙ or higher
  Digital interface
  With address function: RS-485 (transmission speed 38,400 bps)
  F-Net Protocol
  316L Stainless Steel (polished surface)
  Power supply
  +15V±5% 150mA
  -15V±5% 150mA
  Signal response
  Analog: D-Sub 9-pin (TOP)
  Digital: 2 LAN jacks (TOP)
  Standard Fitting *3
  1/4 inch VCR equivalent
  Option: 1.125 inch IGS, 1.5 inch IGS
  1.5 inch IGS
  Free
  Z512/522 Web Ver.001
  Subject to change without notice.